Common Failures of Concrete Mixing Station-Reversing Valve Failure & Component Failure
1. Reversing valve failure The faults of the reversing valve include: the valve can not be reversed or the reversing action is slow, the gas leaks, and the electromagnetic pilot valve is faulty. (1) The reversing valve can't reverse or the reversing action is slow, which is generally caused by poor lubrication, the spring being stuck or damaged, oil pollution or impurities stuck in the sliding part, etc. In this regard, we should first check whether the oil mist device works normally; Whether the viscosity of lubricating oil is appropriate. If necessary, replace the lubricating oil, clean the sliding part of the reversing valve, or replace the spring and reversing valve. (2) After long-term use, the reversing valve is prone to wear of the sealing ring of the valve core and damage of the valve stem and valve seat, resulting in gas leakage in the valve, slow action of the valve or abnormal reversing. At this time, the sealing ring, valve stem and valve seat should be replaced, or the reversing valve should be replaced. (3) If the inlet and...
















