Air Source Fault-One of the Common Faults of Concrete Mixing Station
(1) The faults of air compressor include: damage of check valve, serious wear of piston ring, damage of air inlet valve and blockage of air filter, etc. If you want to judge whether the check valve is damaged, just turn off the power supply after the air compressor stops automatically for more than ten seconds, and turn the big belt wheel by hand. If you can rotate it easily for one week, it shows that the check valve is not damaged. On the contrary, the check valve has been damaged; In addition, it can also be judged from the exhaust situation of the exhaust port under the automatic pressure switch. Generally, after the air compressor stops automatically, it should stop exhausting after about ten seconds. If it stops exhausting until the air compressor starts again, it means that the check valve has been damaged and needs to be replaced. When the pressure of the air compressor rises slowly and is accompanied by oil string phenomenon, it shows that the piston ring of the air compressor has been seriously worn and...